J49 auxiliary power, Cj51 box in, J49 auxiliary power 234 cj51 box in 234 – MTS Model FlexTest SE User Manual

Page 234: J49 auxiliary power 234, Cj51 box in 234, Jumper plug required

Advertising
background image

Models FlexTest® IIm/GT/SE Controller Hardware

J49 Auxiliary Power

FlexTest SE Controller Connections

234

Jumper plug required

If connector J43 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug PN 100-057-245, or jumper pins: 1-2,
3-4.

J49 Auxiliary Power

See

“J49 Auxiliary Power”

on page 140.

CJ51 Box In

Connector J51 Box In allows the Model 493.02 chassis to receive clock,
hydraulic, and interlock signals from another Model 493.02 chassis.

J51 Connector Pin Assignments

P

IN

N

AME

F

UNCTION

1

+clk in

+External clock input

2

hyd high in

Hydraulic high input

3

reset in

Interlock reset request input

4

signal return

Signal return for optically isolated inputs

5

/intlk in

Hydraulic interlock input

6

hyd low in

Hydraulic low input

7

signal return

Signal return for optically isolated inputs

8

master/slave in

Master -/Slave select input

9

- clk in

- External clock input

10

hyd hi return out

Hydraulic high return output

11

reset return out

Interlock reset return output

12

ground

Signal ground

13

/intlk return out

Hydraulic interlock return output

14

hyd low return out

Hydraulic low return output

15

ground

Signal ground

Advertising