Analog chassis plug-in modules, Analog chassis plug-in modules 64 – MTS Model FlexTest SE User Manual

Page 64

Advertising
background image

Models FlexTest® IIm/GT/SE Controller Hardware

Analog Chassis Plug-in Modules

Installation

64

Analog Chassis Plug-in Modules

Before you install any plug-in modules, be sure they are configured properly for
your system. The following is a brief description of the plug-in modules available
for the chassis.

Plug-in Modules

M

ODEL

#

P

LUG

-I

N

M

ODULE

N

AME

F

UNCTION

497.13

*

* This conditioner is normalized and can be swapped (with a conditioner of the same model number)

without recalibrating the sensor/conditioner pair. Normalized conditioners contain an EEPROM in
which normalization values are stored during manufacturing. These values compensate for
variations in conditioner components.

AC Conditioner

Processes signals from AC-type sensors such as LVDTs or
RVDTs.

Note

This module was designed to replace the Model
497.14 AC Conditioner.

497.15

Three-Stage Valve Driver

Produces the control signal and inner control loop for a Series
256 Servovalve or Series 257 Servovalve.

497.22

*

Dual DC Conditioner

Processes the signals from two DC-type sensors such as a

force transducer or extensometer.

497.26

Two-Stage Valve Driver

Produces the control signal for one Series 252 Servovalve.

The second valve driver is not used in standard systems.

497.34

Multistation Interlock
Controller

Monitors the plug-in modules for interlocks. This is a part of
the interlock chain between Model 497.05 Chassis and any

other 497.01 chassis.

497.36

Communication Module

Provides communications between the Model 497.01 Analog

Chassis and the Model 498.22 Test Processor.

Advertising