MTS Model FlexTest SE User Manual

Page 29

Advertising
background image

Specifications

Models FlexTest® IIm/GT/SE Controller Hardware

Introduction

29

FT IIm standard

configurations

4, 6, 8, 12, or 16 channels of control

16 inputs and 16 outputs of user DIO

Per channel resources:

One valve driver output

One D/A output

One A/D input

One AC Conditioned input

Two DC conditioned inputs

Console

The FlexTest IIm Controller is available in a full-bay (vertical) console, a table-
top console, or a roll-around console.

Note

The larger (full-bay) consoles can also accommodate rack-mount
scopes, x-y recorders, and so forth.

Customization

A standard FlexTest IIm system can be customized for specific test requirements.
In these cases, the standard hardware and software can be changed to
accommodate a specific customer requirement.