Models FlexTest® IIm/GT/SE Controller Hardware

Connecting Interlock Signals to 407 Controllers

FlexTest GT Controller Connections

158

Multiple 407 Controller

interlock connections

The following figure shows how to cable interlocks for multiple Model 407
Controllers to the Model 493.10 Chassis (via its Model 493.74 HSM transition
module). Use the specified interlock cable (PN 056-455-0xx) to make these
connections for each Model 407 Controller station.

Run/Stop,

ActiveHigh

Hydraulic

Interlock,

ActiveLow To

407

Controller

(Station 2)

To

493.74

HSM

Transition

Interlock Cable PN 056-455-0XX

Digital

I/O Connector

Jumper

Jumper

Jumper

Run/Stop,

ActiveHigh

Hydraulic

Interlock,

ActiveLow To

407

Controller

(Station 1)

To

493.74

HSM

Transition

Interlock Cable PN 056-455-0XX

Digital

I/O Connector

Jumper

Jumper

Jumper