MTS Model FlexTest SE User Manual

Page 96

Advertising
background image

Models FlexTest® IIm/GT/SE Controller Hardware

Digital Universal Conditioner (DUC BC) Switches

FlexTest GT Controller Connections

96

Bridge balance

Switch S1-5 changes the offset of the bridge balance circuit. If the zero offset is
too large when the sensor bridge is balanced, you should enable this feature (it
adds a 100 k

Ω resistor to the input of the conditioner preamp).

Excitation sense

Switches S1-6 and S1-7 select the local (on board) or remote (through a cable)
excitation sensor connection.

The local selection is used with 4-wire transducer connections.

The remote selection is used with 8-wire transducer connections.

Switch S1-7 configures the + excitation signal.

Switch S1-6 configures the – excitation signal.

Both switches need to be set for the same configuration.

Single ended

excitation

Jumper W8 connects -EX to ground for situations requiring single- ended
excitation.

Default

Disable

Enabl

S1-5 OFF

S1-5 ON

Remote

S1-6 OFF

S1-7 OFF

S1-6 ON

S1-7 ON

Local

Default

Default

–EX = –EX

–EX = GND

W8

W8

Advertising