Analog inputs – MTS Model FlexTest SE User Manual

Page 126

Advertising
background image

Models FlexTest® IIm/GT/SE Controller Hardware

ADDA II Connections

FlexTest GT Controller Connections

126

Analog inputs

The analog-to-digital mezzanine cards accommodate up to eight analog input
signals. Each A/D input signal must be within ±10 volts.

Analog inputs can be connected at the BNC connectors of a Model 493.81
Analog In transition module and the outputs from this module are connected
to the Model 493.50 ADDA II module.

Analog inputs can be connected at the BNC connectors of a Model 493.83
Filtered Analog Input transition module and the outputs from this module
are connected to the Model 493.50 ADDA II module.

Input 1

Input 2

Input 3

Input 4

J 1 1 , J 1 3

J 1 5 , J 1 7

J 1 2 , J 1 4

J 1 6 , J 1 8

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

Input 5

Input 6

Input 7

Input 8

To

A/D

From

493.81 Analog In

Module

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

Advertising
This manual is related to the following products: