Models FlexTest® IIm/GT/SE Controller Hardware

Digital I/O Connections

FlexTest GT Controller Connections

142

Digital inputs

The J3 In connector accommodates up to sixteen digital signals from external
devices. You can use digital input signals to trigger test events with your
controller applications.

All of the inputs are optically isolated and support relay contacts or logic
inputs (see the following figure).

Channel inputs can be 3 volts (minimum) and 26 volts (maximum) from an
external voltage source.

Jumpers select the debounce time for each group of four inputs.

Jumper X2 configures inputs 1–4. Jumper X3 configures inputs 5–8. Jumper
X4 configures inputs 9–12. Jumper X5 configures inputs 13–16.

Not using a jumper sets the debounce to 20 msec.

Jumper pins 1 and 4 to set the debounce to 10 msec.

Jumper pins 2 and 3 to set the debounce to 1 msec.

Jumper pins 1 and 4, and 2 and 3 to set the debounce to 0.1 msec.

J3

+CH1

-CH1

+12

J3

+CH1

-CH1

+12

18

1

20

36

18

1

20

36

External Switch

or

Relay Contact

External Device

External Device

Digital I/O

Access Panel

Digital I/O

Access Panel

493.72 Digital I/O

Transition Module

Opto-

Coupler

493.72 Digital I/O

Transition Module

Opto-

Coupler