Specifications

Models FlexTest® IIm/GT/SE Controller Hardware

Introduction

27

Specifications

FlexTest SE Specifications

P

ARAMETER

S

PECIFICATION

Environmental

Temperature

Relative humidity

Altitude

For indoor use only

5ºC–40ºC (41ºF–104ºF)

10%–85%, noncondensing

For use at altitudes up to 2000 m
(6500 ft)

Power input

Input voltage

*

Input frequency

Input surge

Insulation over
voltage

Pollution degree

* The specification shown conforms to CE Low Voltage Directive

requirements. The specification allows for 10% of the values stated.
The actual voltage the 493.02 chassis can operate is
90–264 V AC.

power factor corrected universal input

100–240 V AC

47–63 Hz

<50 A

Category I

2

Weight

approximately 8.6 kg (19 lb)