Cable specification – MTS Model FlexTest SE User Manual

Page 79

Advertising
background image

UPS Connections for the Model 493.73 HPU Board

Models FlexTest® IIm/GT/SE Controller Hardware

Installation

79

UPS Connections for the Model 493.73 HPU Board (FT60, FT100, FT200, FTGT)

The following drawing shows UPS connections for the Model 493.73 HPU
board. Once connected, use your controller software to add UPS hardware
resources and configure the various UPS options.

Note

Systems that use Series 793 Control Software have Hwi Editor and
station setup settings for UPS systems.

Cable specification

To maintain EMC compliance, J54 SYS DI/O cables must comply with the
following specifications:

Connector–15-contact, type D male EMI connector.

Backshell–metallized plastic or metal.

Cable—26 to 22 AWG, 4-conductor with overall braided shield, with the braided
shield connected to the backshell at the chassis.

+24 V DC

+24 V DC

493.73 HPU Board

J54 SYS DI/O

UPS

SERVICE

493.73

HPU

J23

E-STOP OUT

J24

E-STOP IN

J25 HPU

J54

SYS D I/O

493.73

HPU Board

AC Fail

Contacts

Open = Logic 0

1

2

3

4

5

6

7

8

J54

SYS DI/O

Digital Input 1

Low Battery

Contacts

Open = Logic 0

Digital Input 2

Advertising