MTS Model FlexTest SE User Manual

Page 162

Advertising
background image

Models FlexTest® IIm/GT/SE Controller Hardware

Sending and Receiving Signals to a Model 407

FlexTest GT Controller Connections

162

Sending and Receiving Signals to a Model 407 Controller

After cabling the Model 407 Controller, you must configure it to receive and send
signals from the FlexTest GT Controller. The tables below list typical menu

settings. Refer to the Model 407 Controller Product Information Manual for

more information.

407 Configuration Menu

P

ARAMETER

S

ETTING

Eng Units

—

EOC Act

—

CYC Src

PROGRAM

SetPt R

150%/s (or highest)

Span R

300%/s (or highest)

Hyd Cnfg

—

Intlk Cnfg

MASTER

*

* Always designate one 407 in a station as a MASTER. If there are

other 407s in the same station, daisy-chain their interlocks and
designate them as DEPENDENT.

P/V Sens

—

Span Cnfg

1X

CMD Sel

EXT IN

Prog Out

—

407 Function Generator Menu

P

ARAMETER

S

ETTING

Wvform

EXTERN

Freq

—

Setpnt

—

Span

—

Preset

—