Models FlexTest® IIm/GT/SE Controller Hardware

Transition Module Connectors

Installation

68

Single chassis

configuration

If you have a single analog chassis:

First install a cable from a Series 498 host computer serial port (debug) to J51
Intlk In
on the Model 497.05 Hydraulic Control Panel, then from J52 Intlk Out
to J51 Intlk In on the Model 497.01 Analog Chassis. Then install jumper plug
assembly (PN 046-350-701) to J52 Intlk Out on the analog chassis.

Multichassis

configuration

If you have a multiple analog chassis:

1. Install the cable from the chassis to J51 Intlk In on the Model 497.05

Hydraulic Control Panel, then from J52 Intlk Out to J51 Intlk In on the
first Model 497.01 Analog Chassis (see

“Interlock Connections”

on page

192).

2. Install a chassis interconnect cable from J52 Intlk Out of the first analog

chassis to J51 Intlk In of the next chassis. Install as many cables as needed
to connect all the chassis.

3. On the last chassis, install jumper plug assembly (PN 046-350-701) to J52

Intlk Out.