Remote station controller (rsc) connections, Remote station controller (rsc) connections 203, Hwi file additions – MTS Model FlexTest SE User Manual

Page 203

Advertising
background image

Remote Station Controller (RSC) Connections

Models FlexTest® IIm/GT/SE Controller Hardware

FlexTest IIm Controller Connections

203

Remote Station Controller (RSC) Connections

When equipped with a GRES III plug-in module and a corresponding Series
498 RS-485 transition module, your FlexTest IIm controller can
accommodate up to four remote station controllers (one RSC for each
station).

Each RSC connects to a J50 serial connector on the Series 498 RS-485
transition module. The hwi file defines which connector is used for each
station.

.hwi file additions

In order to use one or more RSCs with your FlexTest controller, two sections
must be added to your .hwi file—an RSC section and a GRES III section.

Note

If you specified RSC support when you ordered your test system,
these sections will be added to your hwi file at the factory.

Note

For information on editing your .hwi file to accommodate RSCs, see
the Hwi File Editor manual.

m

498

RS-485
TRANSITION
MODULE

+12V +5V

J50A

J50B

J50C

J50D

J7 SERIAL

498 RS-485 Transition Module
Cable the RSC to the proper J50 serial
connector (usually J50A) using cable PN
055-634-3XX.

Off

Low

Interlock

HSM

Test

Manual Control

Emergency Stop

F1

F2

F3

F4

Status

Remote Station Control

Enable /
Disable*

Reset

High

Hold

Stop

Run

Off

Low

High

HPS

055-634-3XX

Remote Station Controller

Use Jumper Plug 055-634-101
in these connectors.

Advertising