MTS Model FlexTest SE User Manual

Page 139

Advertising
background image

J44 Run/Stop

Models FlexTest® IIm/GT/SE Controller Hardware

FlexTest GT Controller Connections

139

Output specifications

The specifications for the interlock status opto-isolator outputs are as follows:

•

Output Format: open collector, open emitter transistor

•

Maximum Voltage: 26 V DC

•

Minimum Guaranteed Output Current Drive: 20 mA (30 mA typical) @ 1.0
V max

Jumper X5

Jumper setting X5 selects the source for interlock status output. The following
jumper settings select the indicated interlock source:

•

X5 Jumpered = HSM Board Interlocks Only

•

X5 Not Jumpered = Station and HPU Interlocks

Jumpers W8/W9

Jumper settings W8/W9 determine the output polarity of the opto-isolators.

Cable specification

•

9-contact type D female EMI connector

•

Backshell–EMI metallized plastic

•

Cable–shielded twisted pairs (24 AWG minimum) with drain wire(s)
connected to the metallized backshell at the chassis.