Models FlexTest® IIm/GT/SE Controller Hardware

Introduction

33

Specifications

Model 497.01 Specifications

P

ARAMETER

S

PECIFICATION

Environmental

Temperature

Relative humidity

For indoor use only

5ºC–40ºC (41ºF–104ºF)

10%–85%, relative, noncondensing

Power requirements

+15 V at 6 A; -15 V at 6 A; +5 V at 6 A
(standard supply maximum output,
actual load depends on installed
modules)

Dimensions

Height

Width

Depth

17.8 cm (7 in)

48.3 cm (19 in)

31.1 cm (12.25 in)

Model 497.05 Specifications (part 1 of 2)

P

ARAMETER

S

PECIFICATION

Individual solenoid current

Total HSM solenoid current

2 A max

6 A max

Solenoid operating voltage

24 V DC or 115 V AC (switch
selectable)

497.05 power supply output

497.01 power supply output

+24 V at 7.5 A

+5 V at 6 A

+15 V at 6 A

-15 V at 6 A

Power requirements

90–132 V AC/180 - 264 V AC

47–63 Hz

500 W