Models FlexTest® IIm/GT/SE Controller Hardware

HPU Connections

FlexTest IIm Controller Connections

190

HPU Connections

Cable specification

P25 is a 24-contact CPC female connector (AMP Incorporated)

Cable—18 AWG, 14 conductor rated for 300 V

Compatible with MTS 24 V DC or 115 V AC control cables

Cable assembly numbers PN 039-708-7XX (24 V DC), 039-708-8XX (115
V AC)

Uses special MTS cable material (PN 044-297-301)

Jumper plug

If an HPU is not connected to the digital controller, a jumper plug is required to
maintain the integrity of the interlocks. Use jumper plug 039-719-901 or jumper
pins: 2 and 3; 3 and 7; 9 and 19; 10 and 12; 11 and 16; 17 and 18.

To/From

HPU

2

3

4

5

7

9

10

12

11

14

15

16

17

18

19

Interlock 1

Interlock 2

HPS Ground

Hyd Interlock Reset HPU

Interlock Common

HPU Power

HPU Start

Interlock 3

HPU High

+ Defeat

HPU Common

Voltage (Common)

HPU Defeat

+24 V

J25

To/From

497.05

Connector J25

controls the hydraulic

power unit.