MTS Model FlexTest SE User Manual

Page 160

Advertising
background image

Models FlexTest® IIm/GT/SE Controller Hardware

Connecting Interlock Signals to 407 Controllers

FlexTest GT Controller Connections

160

Interlock connections

for master/dependent

407 Controllers

The following figure shows how to cable interlocks when a master Model 407
Controller is daisy-chained with three other dependent Model 407 Controllers to
run a single test program on a FlexTest GT Controller (via its Model 493.74 HSM
transition module). Use the specified four-channel master/dependent interlock
cable (PN 056-448-9XX) to make these connections for each Model 407
Controller station.

Jumper

Jumper

Jumper

Digital

I/O Connector

Hydraulic

Interlock

Active Low

Hydraulic

Interlock

Active Low

Hydraulic

Interlock

Active Low

Hydraulic

Interlock

Active Low

Run/Stop

Active High

Run/Stop

Active High

Run/Stop

Active High

To

407 Controller

To

407 Controller

To

407 Controller

To

407 Controller

Run/Stop

Active High

To

493.74

HSM

Transition

Master/Dependent Interlock Cable

(PN 056-448-9XX)

Master

Dependent

Dependent

Dependent

Advertising
This manual is related to the following products: