Models FlexTest® IIm/GT/SE Controller Hardware

ADDA II Connections

FlexTest GT Controller Connections

128

ADDA II Universal

Encoder connections

Each encoder requires a Model 493.59 Universal Encoder mezzanine card
installed on the Model 493.50 ADDA II module.

Up to four encoders can be connected to the Model 493.80 ADDA II Encoder
Transition module when the Model 493.50 ADDA II module is fully populated
with Universal Encoder cards.

J 1 1 , J 1 3

J 1 5 , J 1 7

J 1 2 , J 1 4

J 1 6 , J 1 8

Input 4

Return Gnd
Index Ser Clk
B/Interrogate
A/Serial Data

Input 3

Return Gnd
Index Ser Clk
B/Interrogate
A/Serial Data

Input 2

Return Gnd
Index Ser Clk
B/Interrogate
A/Serial Data

Input 1

Return Gnd
Index Ser Clk
B/Interrogate
A/Serial Data

To/From

Encoder Transition

Module

1
2
3
4
5
6
7
8

9

1 0
1 1
1 2
1 3
1 4
1 5
1 6

Advertising