Front panel vmebus modules m, I/o carrier mezzanine cards (part 1 of 2) m – MTS Model FlexTest SE User Manual

Page 45

Advertising
background image

VMEbus Modules

Models FlexTest® IIm/GT/SE Controller Hardware

Installation

45

The rotary dipswitch settings for address C40 are shown below. Increment the
front panel dipswitch as required to complete ADDA II module addressing.

0

2

3

4

5

6

7

8

9

A

C

E

1

F

S2

0

2

3

4

5

6

7

8

9

A

C

E

1

F

S3

0

2

3

4

5

6

7

8

9

A

C

E

1

F

On ADDA II

Front Panel

Front Panel VMEbus Modules

M

ODEL

M

ODULE

N

AME

F

UNCTION

493.40

I/O Carrier

Supports up to four mezzanine cards.

493.43

Multi-Box I/O

The optional module allows multiple controllers to share a
master hardware synchronization clock and pass station
interlock state information between each other.

493.50

ADDA II

This optional module supports up to four 8-channel A/D
(Model 493.55) or D/A (Model 493.56) mezzanine cards. This
module also supports the 8-channel DSPAD, 8-channel
Delta-Sigma A/D, and 4-channel Universal Encoder
mezzanine cards.

498.96-X

Processor

Provides an interface between the controller and an external
computer. The processor module also manages the plug-in
modules and transition panels.

498.71B

GRES III

Interfaces with a Remote Station Control (RSC) module and
temperature controllers.

I/O Carrier Mezzanine Cards (part 1 of 2)

M

ODEL

M

ODULE

N

AME

F

UNCTION

493.14

Valve Driver

Produces the control signal for a Series 252 Servovalve.

493.15

3–Stage Valve Driver

Produces the control signal for a Series 256 or 257
Servovalve.

493.21B

Universal Conditioner

Processes the signals from either an AC or DC-type sensors.

493.25

Universal Conditioner

Processes the signals from either an AC or DC-type sensors.

493.45

A/D

Converts up to six external analog signals to digital signals for
use by the controller.

Advertising