J55 Digital Outputs

Models FlexTest® IIm/GT/SE Controller Hardware

FlexTest SE Controller Connections

237

J55 Digital Outputs

Connector J55 Dig Out provides three general purpose digital outputs that can
send digital logic signals to external switches or logic devices.

The digital output relays are rated for a maximum of 1 Amp max, 30 V DC/
AC max.

The outputs are optically isolated.

Cable specification

The cabling information shown assumes a single cable destination (with an
overall shield). In other applications, the cable may have more than one
destination. For these applications an overall shield is not practical and non-EMI
connectors and back shells are permissible.

9 pin contact type D male EMI connector

Back shell–EMI metallized plastic

Cable–shielded twisted pairs as required (24 AWG minimum) with drain
wire(s) connected to the metallized backshell at the chassis.

Run/Stop setup

If required, digital output 1 (pins 1 and 2) can be set up as a Run/Stop connector.
Use the following procedures to set up this Run/Stop connector:

Relay Contact

Relay Contact

Relay Contact

To

External Device

J55

1

2

3

4

5

6

7

8

9

Channel 1 Output

Channel 2 Output

From

FT SE Controller

Channel 3 Output

+24 V

Advertising