Hydraulic Configurations

This section describes how to connect the Model 493.10 Chassis (FlexTest GT
Controllers) and the Model 493.02 Chassis (FlexTest SE) to a variety of MTS
hydraulic configurations.

Use the following connectors and cables to connect the Model 493.10/02 Chassis
to your HPU with a Model 493.07 Converter Box:

Note

For jumpering information, see Appendix B: Model 493.07 Converter Box
on

page 251

.

Models 493 Chassis to

493.07 Converter Box

15 contact type D female EMI connector at J25 of the Model 493.73 HPU
Transition module in the rear panel of the Model 493.10 Chassis.
Backshell–EMI metallized plastic.

14 contact type CPC male connector at J1 of the Model 493.07 Converter
Box chassis.

Cable–24 AWG 10 conductor with overall foil shield, (Carol C0745 or
equivalent) with drain wire connected to metallized plastic backshell at the
493.10 chassis, and pin 14 at the Model 493.07 Controller Box chassis.

Model 493.07 Converter

Box to HPU

24 contact type CPC female connector at J25 of the Model 493.07 Converter
Box chassis.

14 contact type MS connector at J1 of the HPU.

Cable—18 AWG 14 conductor with overall foil shield, (Alpha 2248C or
equivalent) with drain wire connected to pin 4 of connector J25 and pin A of
the pump connector.

Hydraulic pump

configurations

The following diagrams show how to connect the chassis to a hydraulic power
unit.

Single 493 chassis with a 24 V PLC (programmable logic controller) pump
or 505 pump

Single 493 chassis with a non-PLC pump

Multiple 493 chassis with a non-PLC pump

Compatible controllers controlling a pump