3.3.2
Closing LH Endshield
1. Move the endshield (A) slightly so that support (B) can
be moved out of lock position.
Figure 3.3: Disengaging Support
2. Close shield (A), ensuring that magnet (B) and stop (C)
in header frame are aligned. This will ensure that the
latch (D) will line up with the receptacle (E).
NOTE:
Latch (D) and magnet (B) positions are properly
adjusted at the factory.
Figure 3.4: Closing Endshield
3. If required, loosen nuts (B) on clips (C) at the back of
the shield (A) and reposition the shield. Tighten the
nuts (B) but do not overtighten to prevent damage to
the shield.
Figure 3.5: Adjusting Endshield