Metric Bolt Specifications Bolting into Cast Aluminum
Table 4.5 Metric Bolt Bolting into Cast Aluminum
Bolt Torque
8.8
(Cast Aluminum)
10.9
(Cast Aluminum)
Nominal
Size
ft·lbf
N·m
ft·lbf
N·m
M3
1
M4
2.6
4
M5
5.5
8
M6
6
9
9
12
M8
14
20
20
28
M10
28
40
40
55
M12
52
70
73
100
M14
M16
Figure 4.2
A - Nominal Size
Flare-Type Hydraulic Fittings
1. Check flare (A) and flare seat (B) for defects that might
cause leakage.
2. Align tube (C) with fitting (D) and thread nut (E) onto
fitting without lubrication until contact has been made
between the flared surfaces.
3. Torque the fitting nut (E) to the specified number of
FFFT or to a given torque value shown in the following
table.
4. To prevent the fitting (D) from rotating, use two
wrenches. Place one wrench on the fitting body (D)
and tighten the nut (E) with the other wrench to the
torque shown.
5. Assess the final condition of the connection.
Figure 4.3
A - Flare
B - Flare Seat
C - Tube
D - Body
E - Nut
169489
79
Revision A