Flare-type hydraulic fittings, Table 4.5 metric bolt bolting into cast aluminum – MacDon PW8 Pick-Up Header User Manual

Page 87

Advertising
background image

MAINTENANCE AND SERVICING

Metric Bolt Specifications Bolting into Cast Aluminum

Table 4.5 Metric Bolt Bolting into Cast Aluminum

Bolt Torque

8.8

(Cast Aluminum)

10.9

(Cast Aluminum)

Nominal

Size

ft·lbf

N·m

ft·lbf

N·m

M3

1

M4

2.6

4

M5

5.5

8

M6

6

9

9

12

M8

14

20

20

28

M10

28

40

40

55

M12

52

70

73

100

M14

M16

Figure 4.2

A - Nominal Size

Flare-Type Hydraulic Fittings

1. Check flare (A) and flare seat (B) for defects that might

cause leakage.

2. Align tube (C) with fitting (D) and thread nut (E) onto

fitting without lubrication until contact has been made
between the flared surfaces.

3. Torque the fitting nut (E) to the specified number of

FFFT or to a given torque value shown in the following
table.

4. To prevent the fitting (D) from rotating, use two

wrenches. Place one wrench on the fitting body (D)
and tighten the nut (E) with the other wrench to the
torque shown.

5. Assess the final condition of the connection.

Figure 4.3

A - Flare

B - Flare Seat

C - Tube

D - Body

E - Nut

169489

79

Revision A

Advertising