Instance 103

This input (produced) assembly was included in the Series B MDSA. Its length (in bytes) is
equal to the number of I/O modules on the back-plane plus 4 bytes of status information. It
has the following format:

Instance 105

This is the default input (produced) assembly for the Cat. No. 198-DNG. It was included in
the Series B MDSA as the default produced assembly. It is eight bytes long (6 I/O modules
on an MDSA gland plate, plus 2 bytes of status). It has the following format:

Table A.21 Instance 103 — Modular Input Assembly Instance for
Cat. No. 198-DNG

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Location 1 Location 0 Status 6

Status 5

Status 4

Status 3

Status 2

Status 1

1

Error 6

Error 5

Error 4

Error 3

Error 2

Error 1

Error 0

Location 2

2

Location 7 Location 6 Location 5 Location 4 Location 3 Location 2 Location 1 Location 0

3

Error 7

Error 6

Error 5

Error 4

Error 3

Error 2

Error 1

Error 0

4

Module 1 data

5

Module 2 data

6

Module 3 data

:

:

:

:

n

Module n data

Table A.22 Instance 105 — Default Input Assembly Instance for Cat. No. 198-DNG

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Location 1 Location 0 Status 6

Status 5

Status 4

Status 3

Status 2

Status 1

1

Error 6

Error 5

Error 4

Error 3

Error 2

Error 1

Error 0

Location 2

4

Module 1 data

5

Module 2 data

6

Module 3 data

7

Module 4 data

8

Module 5 data

9

Module 6 data