background image

B-2 Motor Starter Operation

Publication 198-UM002A-EN-P December 2001

Setting the Motor Starter Type

The following example shows how to set up the 198-DNG DeviceNet module to identify
itself on the network as a Bulletin 190-D Distributed Starter.

1. From the “Device Parameters” screen for the unit being programmed, change the

Motor Starter Type parameter (param 51) to the value “Distributed Str” as shown below.

Table B.1

Motor
Starter
Type

Description

Vendor
ID

Product
Type

Product
Code

Default
Output
Assembly

Default Input
Assembly

0

Not a Standard Starter

1

12

98

104

105

1

190-D Distributed Starter

1

22

1

150

151

2

191-D Reversing Distributed Starter 1

22

2

152

153

3

160-D Inverter Type Distributed
Starter

1

22

3

154

155

TIP