Setting the motor starter type – Rockwell Automation 198 Series C Modular DeviceNet Starter Auxiliary User Manual User Manual
Page 170
![background image](/manuals/577535/170/background.png)
B-2 Motor Starter Operation
Publication 198-UM002A-EN-P December 2001
Setting the Motor Starter Type
The following example shows how to set up the 198-DNG DeviceNet module to identify
itself on the network as a Bulletin 190-D Distributed Starter.
1. From the “Device Parameters” screen for the unit being programmed, change the
Motor Starter Type parameter (param 51) to the value “Distributed Str” as shown below.
Table B.1
Motor
Starter
Type
Description
Vendor
ID
Product
Type
Product
Code
Default
Output
Assembly
Default Input
Assembly
0
Not a Standard Starter
1
12
98
104
105
1
190-D Distributed Starter
1
22
1
150
151
2
191-D Reversing Distributed Starter 1
22
2
152
153
3
160-D Inverter Type Distributed
Starter
1
22
3
154
155
TIP
Setting the motor starter type is optional. It is convenient because it
simplifies identity on the network.