Printed circuit board replacement – Rockwell Automation 7000A PowerFlex Medium Voltage AC Drive - Air-Cooled (A Frame) User Manual

Page 315

Advertising
background image


Component Definition and Maintenance 5-73

7000 “A” Frame

7000A-RM001A-EN-P – January 2011

M4 (P.H.M.S.) and

nylon shoulder washer

Mounting plate

Black insulation

Part ID label

DC/DC

Power Supply

M6 (H.H.T.R.S.)

VIEW “1”

VIEW “2”

Figure 5.57 – Replacement of DC/DC power supply


The replacement of printed circuit boards should be handled in a careful
manner.


There are some basic precautions that should be taken. They include the
following:

Remove all power to the drive.

Do not remove the replacement board from the anti-static bag until

necessary.

Use anti-static wrist strap, grounded in the Low Voltage Control

Section


There are no direct screw/terminal connections on any of the Low Voltage
circuit boards. All wire/terminal connections are made with plugs that
plug into the circuit boards. This means that changing boards only
requires the removal of the plugs, minimizing the chance of mistakes
when reconnecting all of the wiring.

Printed Circuit Board
Replacement