Appendix

A

7000 “A” Frame

7000A-RM001A-EN-P – January 2011

Catalog Number Explanation

for PowerFlex 7000 Variable Frequency Drives

First Position

Second Position

Third Position

Fourth Position

Fifth Position

Sixth Position

Seventh Position

7000

A

40

D

A

RPDTD

1 - … etc.

Bulletin

Number

Service Duty/

Altitude Code

Current

Rating

Enclosure

Type

Line and

Control

Voltages

Rectifier

Configuration/

Line Impedance

Type

Options

(Refer to

PowerFlex 7000

Medium Voltage Drives

Global Price List)

Code

Description

A

Normal Duty, 0-1000 m Altitude
Maximum 40°C Ambient

B

Normal Duty, 1001-5000 m Altitude
Reduced Ambient (from 40°C offering)

1001 – 2000 m = 37.5°C
2001 – 3000 m = 35°C
3001 – 4000 m = 32.5°C
4001 – 5000 m = 30°C

C

Heavy Duty, 0-1000 m Altitude
Maximum 40°C Ambient

D

Heavy Duty, 0-5000 m Altitude
Reduced Ambient (from 40°C offering)
– Same as ‘

B’ above

E

Normal Duty, 0-1000 m Altitude
Maximum 35°C Ambient

F

Normal Duty, 1001-5000 m Altitude
Reduced Ambient (from 35°C offering)

1001 – 2000 m = 32.5°C
2001 – 3000 m = 30°C
3001 – 4000 m = 27.5°C
4001 – 5000 m = 25°C

G

Heavy Duty, 0-1000 m Altitude
Maximum 35°C Ambient

J

Normal Duty, 0-1000 m Altitude
Maximum 50°C Ambient

L

Heavy Duty, 0-1000 m Altitude
Maximum 50°C Ambient

N

Normal Duty, 0-1000 m Altitude
Maximum 20°C Ambient

Z

Custom Configuration
(Contact Factory)

Code

Description

7000A

“A” Frame (Air Cooled)

7000

“B” Frame (Air Cooled)

7000L

“C” Frame (Liquid Cooled)

Code

Description

D

Type 1 w/gasket (IP21)

T

Type 1 w/gasket (IP21)
– Seismic rated

K

Type 12 w/vents and
filters (IP42)

U

Type 12 w/vents and
filters (IP42) – Seismic
rated

Code

Description

RPDTD

AFE Rectifier with Integral Line
Reactor and Direct-to-Drive DC
Link

RPTX

AFE Rectifier with provision for
connection to separate Isolation
Transformer (standard DC Link)

RPTXI

AFE Rectifier with integral Isolation
Transformer (standard DC Link)

RPLR

AFE Rectifier with Integral Line
Reactor and Standard DC Link
(No longer offered for sale)

R6TX

6-pulse Rectifier with provision for
connection to separate Isolation
transformer (standard DC Link)
(No longer offered for sale)

R18TX

18-pulse Rectifier with provision for
connection to separate Isolation
Transformer (standard DC Link)

See Table A-1

Code

Description

40

40 Amp

46

46 Amp

53

53 Amp

61

61 Amp

70

70 Amp

81

81 Amp

93

93 Amp

105

105 Amp

120

120 Amp

140

140 Amp

160

160 Amp

185

185 Amp

215

215 Amp

250

250 Amp

285

285 Amp

325

325 Amp

375

375 Amp

430

430 Amp

495

495 Amp

575

575 Amp

625

625 Amp

657

657 Amp

720

720 Amp

Not all amperages are
available at all ambient/
altitude configurations.
Refer to Price Lists for
exact offering.