Uploading a parameter profile – Rockwell Automation 8720MC Drives Integration Manual User Manual
Page 106

Publication 8720MC-IN002A-EN-P — December 2002
B-12
Using the Human Interface Module (HIM)
Uploading a Parameter Profile
You can transfer a parameter profile from the 8720MC Drive to a
remote HIM, Cat. No. 1201-HAx, as a means of transferring a
parameter set from one 8720MC to another. This functionality is not
available with the 8720MC built in HIM. To upload a parameter profile
from the drive to the HIM:
1. From the EEProm mode prompt, press the increment up key or
the decrement down key until “Drive -> HIM” is displayed.
2. Press a - A profile name (up to 14 characters) is displayed on line
2 of the HIM.
3. Change this name or enter a new name. Use the increment up key
to move the cursor to the left. Use the increment up key or the
decrement down key to change the characters.
4. Press enter. An informational display is shown. This display
indicates the drive type and firmware version.
5. Press enter to start the upload. The parameter number currently
being uploaded is displayed on line I of the HIM. Line 2 indicates
the total progress. Press ESC to stop the upload.
6. Press enter when “COMPLETE” is displayed on line 2. If line 2
reports “ERROR”, refer to Chapter 3.