Publication 8720MC-IN002A-EN-P — December 2002

Commissioning Your 8720MC SERCOS Interface Drive

1-7

Configuring Your
1756-Mxx
SE SERCOS
Interface Module

This procedure assumes that you have wired your 8720MC system and
have configured the 8720MC baud rate and optical power switches.

Note: For detailed configuration information, refer to the ControlLogix

Motion Module Setup and Configuration Manual (publication
1756-UM006x-EN-P).

To configure your 1756-MxxSE SERCOS interface module and create a
program including your 8720MC drive:

1.

2. Apply power to your ControlLogix chassis containing the

1756-MxxSE SERCOS interface module and open your RSLogix
5000 software.

3. Select New in the File menu. The New Controller window opens.

4. Provide/select the following New Controller attributes:

Controller type

File name

ControlLogix chassis size

ControlLogix processor slot

5. Select OK.

IMPORTANT

In order for the 8720MC to communicate with the
1756-MxxSE SERCOS interface module, (indicated by
the three LEDs on the 1756-MxxSE going solid
green) your RSLogix 5000 software must be version
11.0 or above.

If you have:

Then:

Already configured your 1756-MxxSE
SERCOS interface module using the
ControlLogix Motion Module Setup
and Configuration Manual

(publication 1756-UM006x-EN-P)

Go to section
Applying Power to
Your 8720MC.

Not configured your 1756-MxxSE
SERCOS interface module

Go to step 2.

IMPORTANT

Refer to the ControlLogix Motion Module Setup
and Configuration Manual
(publication
1756-UM006x-EN-P) for specific instructions and
troubleshooting.