Name: Vel_Integ_Err

Data Display: Signed Decimal

R

Parameter No.
516
File:
Control
Group:
Velocity

Description: This parameter contains the velocity loop integral gain multiplied by the integrator. This is the
integrator’s contribution to the acceleration command.

Default:
65535

Length
2 bytes

SCANport Min/Max
Min.

≥ 0

Max.

≤ 65535

SCANport Scaling Resolution
1 = 1rad/sec2

Units

rad/sec

2

Default:
0.0

Length
4 bytes

SERCOS/DPI Min/Max

Min.

≥ -2

31

Max.

≤ +2

31

- 1

SERCOS/DPI Scaling Resolution
Scaling type: parameter 160
Scaling factor: parameter 161
Scaling exponent: parameter 162

Units
parameter
160

Name: Id_Reference

Data Display: Signed Decimal

R

Parameter No.
517
File:
Control
Group:
Torque

Description: This parameter displays the present level of the Id current reference for the axis.

Default:
65535

Length
2 bytes

SCANport Min/Max
Min.

≥ 0

Max.

≤ 65535

SCANport Scaling Resolution
1 = 1rad/sec2

Units

rad/sec

2

Default:
0.0

Length
4 bytes

SERCOS/DPI Min/Max

Min.

≥ 0

Max.

≤ 10,000

SERCOS/DPI Scaling Resolution
Scaling type: parameter 160
Scaling factor: parameter 161
Scaling exponent: parameter 162

Units
parameter
160

Name: Drive Utilized

Data Display: Signed Decimal

R

Parameter No.
518
File:
Mtr/Drive/Fdbk
Group:
Drive Data

Description: This parameter displays the present level of the current output to the motor as a percent of drive
rated.

Default:
65535

Length
2 bytes

SCANport Min/Max
Min.

≥ 0

Max.

≤ 65535

SCANport Scaling Resolution
1 = 1rad/sec2

Units

rad/sec

2

Default:
0.0

Length
4 bytes

SERCOS/DPI Min/Max

Min.

≥ 0

Max.

≤ 1000

SERCOS/DPI Scaling Resolution
Scaling type: parameter 160
Scaling factor: parameter 161
Scaling exponent: parameter 162

Units
parameter
160