Publication 8720MC-IN002A-EN-P — December 2002

C-66

Programming Parameters

Name: Analog_Out _Parm

Data Type: Integer

R/W

Parameter No.
715
File:
Communication
Group:
SCANp_Ref/
fdback

Description: Parameter 715 contains the linkable parameter number for the SCANport analog output. The value
transferred is a 16 bit integer variable within the 8720MC. Examples of common links are: parameter 40, velocity
feedback, parameter 84, torque feedback, parameter 347, velocity error, parameter 386, motor shaft power etc.
See Supplemental Troubleshooting Information in Chapter 3 for a description of the potential links. Parameter 715
contains the parameter number of a linkable variable. This output is available to a SCANport connected
communication gateway as the reference feedback.

Default:
36

Length
2 bytes

Minimum/Maximum
Min.

≥ 0

Max.

≤ +1000

Scaling Resolution
see parameter definition for the linked variable. For
velocity: 1 = 1 rpm, for torque 1 = .1 %

Units
parameter
address

Name: SP_Logic_Mask

Data Type: 16 bit word, Bit Pattern

R/W

Parameter No.
716
File:
Communication
Group:
SCANp Data In

Description: The 8720MC drive can be operated by an A-B PLC via a SCANport gateway. Parameter 716 is used
to set the SCANport logic mask bits. This function may be used to enable or prevent some of the SCANport nodes
from controlling the 8720MC. This is a 16 bit word with a bit pattern which the 8720MC defines as follows:
If a bit is set true (1) the function is enabled.
Bit 0: Digital I/O Tables 6.1 and 6.2
Bit 1: Port control 1
Bit 2: Port control 2
Bit 3: Port control 3
Bit 4: Port control 4
Bit 5: Port control 5
Bit 6: Port control 6 Embedded HIM Module

Default:
x1111111

Length
2 bytes

Minimum/Maximum
N/A

Scaling Resolution
N/A

Units
N/A

Name: Logic_Command

Data Type: 16 bit word, Bit Pattern

R

Parameter No.
717
File:
Communication
Group:
SCANp Data In

Description: The 8720MC drive can be operated by an A-B PLC via a SCANport gateway. Parameter 717
contains the “Logic Command” word coming from the gateway product. This is a 16 bit word with a bit pattern
which the 8720MC defines as follows:
If a bit is set true (1) the function is enabled.
Bit 0: Regenerative stop request
Bit 1: Start request
Bit 2: Jog request
Bit 3: Drive Error Reset request
Bit 4: Coast stop request
Bit 5: Parameter Set Select bit 0
Bit 6: Parameter Set Select bit 1
Bit 7: Parameter Set Select bit 2
Bit 8: Parameter Set Change
Bit 9: Orient Request,
Bit 10: Reserved
Bit 11: Manual/Auto request, 1 = manual
Bits 12 to 15 are reserved:
The Scanport Logic command word is used by the 8720MC when it is configured for SCANport PLC operation as
determined by parameter 501

Default:
00

Length
2 bytes

Minimum/Maximum
N/A

Scaling Resolution
N/A

Units
N/A