C-2

Programming Parameters

Parameter Files, Groups,
and Elements
(Group Listing)

This section provides parameters supported by the 8720MC drive
listed by group, file, and element.

Parameter
Number

Element Name

Parameter
Number

Element Name

Parameter
Number

Element Name

Parameter
Number

Element Name

File: Group

File: Group

File: Group

File: Group

Status Faults: Drive Status

Control: Velocity

Control: Torque

Procedure: Homing*

13

Drive Status

36

Vel Command

80

Torque Command

147*

Homing Parameter

182

A-B Drive Status

40

Velocity Fback

84

Torque Fback

400*

Homing Switch

95

Diagnostic Msg

37

Velocity Offset

81

Torque Offset

298*

Home Sw Distance

380

DC Bus Voltage

43

Vel Polarity

85

Torque Polarity

52*

Ref Distance 1

386

Mtr Shaft Power

44

Vel Scale Type

86

Torq Scale Type

54*

Ref Distance 2

520

Cur Limit Source

45

Vel Scaling

93

Torque Scaling

407*

Homing Enable

532

Pwr Sup Utilized

46

Vel Exponent

94

Torque Exponent

529*

Auto Ref Enabled

533

Bus Reg Utilized

91

+/- Vel Limit

573

Torq Scale Gain

150*

Mtr Marker Ofset

563

Regen Energy Val

695

Analog Vel Scale

517

Id Reference

151*

Aux Marker Ofset

14

Commun Errors

696

Manual Vel Scale

992

Id Feedback

403*

Posn Fdbk Status

661

Output Image

347

Velocity Error

520

Cur Limit Source

690

Input Image

516

Vel Integ Err

92

+/- Torque Limit

Procedure: Orient

717

Logic Command

551*

Velocity Droop

519

+Dyn Iq Limit

154

Orient Options

718

SP Logic Status

155*

Friction Comp

536

-Dyn Iq Limit

582

Auto Home

988

Vel Bandwidth

155*

Friction Comp

103

Modulo Value

Status/Faults: Errors

989

Vel Damping

997*

Iq Knff

150

Mtr Marker Ofset

11

Shut Down Errors

534*

Integ Hold En

998*

Id Knff

151

Aux Marker Ofset

129

A-B Fault

106

Cur Bandwidth

152

Spin Orient Req

14

Commun Errors

Control: Position

571

Stopping Torque

153

Orient Angle

95

Diagnostic Msg

47

Position Command

572

Stop Time Limit

222

Spin Orient Spd

99

Drive Err Reset

51

Motor Posn Fback

260

Posn Acc Rate

53

Aux Posn Fback

Control: Acceleration

Status/Faults: Setup

55

Posn Polarity

194*

Accel Command

Procedure: Registration*

504*

Config Options

76

Pos Scaling Type

564*

Accel Feedback

169*

Reg Edge Config

601*

Soft Ovrtrvl Act

77

Lin Posn Scaling

138

+/- Accel Limit

170*

Reg Procedure

602*

Pos Err Flt Act

78

Lin Posn Expon

160

Acc Scale Type

405*

Reg 1 Enable

604*

Fdbk Nse Flt Act

79

Rot Posn Resolut

161

Accel Scaling

401*

Reg 1 State

606*

Mt Therm Flt Act

103

Modulo Value

162

Accel Exponent

406*

Reg 2 Enable

605*

Dr Therm Flt Act

189

Posn Foll Error

260

Posn Acc Rate

402*

Reg 2 State

607*

Enable Swtch Act

986

Pos Bandwidth

516

Vel Integ Err

584*

Reg 1 Window Min

384

HeatSink Temp

987

Pos Damping

585*

Reg 1 Window Max

528

Enable Brake Sol

515

Posn Integ Err

Control: Registration*

586*

Reg 2 Window Min

207

Drive Off Delay

258

Target Position

130*

Reg 1 Rising

587*

Reg 2 Window Max

206

Drive On Delay

177

Abs Distance 1

131*

Reg 1 Falling

57

In Posn Value

178*

Abs Distance 2

132*

Reg 2 Rising

Procedure: Parameter Switch

124

Zero Spd Window

133*

Reg 2 Falling

216

Switch Param Set

125

Speed Threshold

171*

Calc Displacemnt

217

Select Param Set

126

Torque Threshold

52*

Ref Distance 1

254

Actual Param Set

157

At Spd Window

54*

Ref Distance 2

159

Max Foll Error

410*

-Reg 1 Latch

220

Min Spindle Spd

409*

+Reg 1 Latch

221

Max Spindle Spd

412*

-Reg 2 Latch

272

Speed Window %

411*

+Reg 2 Latch

173*

Marker Posn A

174*

Marker Posn B

* Used only with SERCOS interface