Rockwell Automation 8720MC Drives Integration Manual User Manual

Page 196

Advertising
background image

Publication 8720MC-IN001D-EN-P — December 2002

D-8

8720SM Motor Specifications and Performance Curves

Figure D.3
8720SM-011S1DA Motor with 8720MC-B027 Drive

Figure D.4
8720SM-015S2EA Motor with 8720MC-B034 Drive

Figure D.5
8720SM-018S2FA Motor with 8720MC-B042 Drive

0

2

4

6

8

10

12

14

16

18

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

RPM

kW

Maximum kW

Continuous (S1) kW

S6 (50%ED) kW

Amps at Base Speed -
Cont Amps 26.8
S6 Amps 34.6
Max Amps 37.6

0

12

24

36

48

60

72

84

96

108

120

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

RPM

Torque in N-m

Maximum

Torque in N-m
Rated 70
S6-50% 95
Max. 105

S6-50%

Rated

Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.

0

5

10

15

20

25

0

1000

2000

3000

4000

5000

6000

7000

8000

RPM

kW

Continuous (S1) kW

Maximum kW

S6 (50%ED) kW

Amps at Base Speed -
Cont Amps 33.4
S6 Amps 39.1
Max Amps 46

0

15

30

45

60

75

90

105

120

135

150

0

1000

2000

3000

4000

5000

6000

7000

8000

RPM

Torque in N-m

Maximum

Torque in N-m
Rated 96
S6-50% 118
Max. 140

S6-50%

Rated

Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.

0

5

10

15

20

25

30

0

1000

2000

3000

4000

5000

6000

7000

8000

RPM

kW

S6 (50%ED) kW

Continuous (S1) kW

Maximum kW

Amps at Base Speed -
Cont Amps 41.4
S6 Amps 47.2
Max Amps 57

0

18

36

54

72

90

108

126

144

162

180

0

1000

2000

3000

4000

5000

6000

7000

8000

RPM

Torque in N-m

Maximum

Torque in N-m
Rated 118
S6-50% 140
Max. 176

S6-50%

Rated

Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.

Advertising