Name: Velocity_Polarity

Data Display: Enumeration of Choices

R/W

Parameter No.
43
File:
Control
Group:
Velocity

Description: Velocity polarity parameter. This parameter is used to switch polarities of velocity data for specific
applications. Polarities are not switched internally but externally (on the input and output) of a closed loop system.
The motor shaft turns clockwise when there is a positive velocity command difference and no inversion is
programmed. SERCOS interface only.

Enumeration:
Structure of velocity polarity parameter:
Bit 0 – Velocity command value

0 = non-inverted
1 = inverted

Bit 1 – Additive velocity command value (SERCOS interface only)

0 = non-inverted
1 = inverted

Bit 2 – Velocity feedback value

0 = non-inverted
1 = inverted

Bits 15-3 (reserved)
This parameter is available with the 8720MC SERCOS interface.

Default:
x000

Length
2 bytes

Minimum/Maximum
N/A

Scaling Resolution
N/A

Units
N/A

Name: Vel_Scale_Type

Data Display: Bit Pattern

R/W

Parameter No.
44
File:
Control
Group:
Velocity

Description: SERCOS Velocity Data Scaling Type. A variety of scaling methods can be selected by means of the
scaling type parameter. Bit 5 is set to “minutes” for preferred data.

Enumeration:
Structure of velocity data scaling type:
Bits 2–0: Scaling method

000 = no scaling
001 = linear scaling
010 = rotational scaling

Bit 3:

0 = preferred scaling
1 = parameter scaling

Bit 4: Units for linear scaling

0 = meters (m)
1 = inches (in)

Bit 4: Units for rotational scaling

0 = revolutions (R)
1 = (reserved)

Bit 5: Time units

0 – minutes (min)
1 – seconds (s)

Bit 6: Data reference

0 – at the motor shaft
1– at the load

(all other bits are reserved)
This parameter is available with the 8720MC SERCOS interface.

Default
x000x010:

Length
2 bytes

Minimum/Maximum
N/A

Scaling Resolution
N/A

Units
N/A