8720SM Motor Specifications and Performance Curves

D-9

Figure D.6
8720SM-022S2GA Motor with 8720MC-B048 Drive

Figure D.7
8720SM-030S4JA Motor with 8720MC-B065 Drive

Figure D.8
8720SM-037S4KA Motor with 8720MC-B078 Drive

0

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

RPM

kW

Maximum kW

S6 (50%ED) kW

Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.

Amps at Base Speed -
Cont Amps 13.5
S6 Amps 17.2
Max Amps 18.7

6

12

18

24

30

36

42

48

54

60

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

RPM

Torque in N-m

S6-50%

Rated

Maximum

Torque in N-m
Rated 35
S6-50% 47.5
Max. 52.5

Continuous (S1) kW

9

8

7

6

5

4

3

2

1

0

0

5

10

15

20

25

30

35

40

45

50

0

1000

2000

3000

4000

5000

6000

7000

RPM

RPM

kW

Maximum kW

S6 (50%ED) kW

Continuous (S1) kW

Amps at Base Speed -
Cont Amps 63.1
S6 Amps 74.6
Max Amps 88.5

0

30

60

90

120

150

180

210

240

270

300

0

1000

2000

3000

4000

5000

6000

7000

Torque in N-m

Maximum

Torque in N-m
Rated 192
S6-50% 235
Max. 288

S6-50%

Rated

Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.

0

10

20

30

40

50

60

0

1000

2000

3000

4000

5000

6000

7000

RPM

RPM

kW

Maximum kW

S6 (50%ED) kW

Continuous (S1) kW

Amps at Base Speed -
Cont Amps 76.1
S6 Amps 89.2
Max Amps 107

0

36

72

108

144

180

216

252

288

324

360

0

1000

2000

3000

4000

5000

6000

7000

Torque in N-m

Maximum

Torque in N-m
Rated 238
S6-50% 285
Max. 355

S6-50%

Rated

Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.