Rockwell Automation 8720MC Drives Integration Manual User Manual

Page 202

Advertising
background image

Publication 8720MC-IN001D-EN-P — December 2002

D-14

8720SM Motor Specifications and Performance Curves

Figure D.11
8720SM-063S5QA Motor with 8720MC-D120 Drive

Figure D.12
8720SM-075S6SA Motor with 8720MC-D149 Drive

Figure D.13
8720SM-093S6TA Motor with 8720MC-D180 Drive

0

10

20

30

40

50

60

70

80

90

100

0

1000

2000

3000

4000

5000

RPM

kW

Maximum kW

S6 (50%ED) kW

Continuous (S1) kW

Amps at Base Speed -
Cont Amps 117.5
S6 Amps 135
Max Amps 163

RPM

0

60

120

180

240

300

360

420

480

540

600

0

Torque in N-m

1000

2000

3000

4000

5000

Maximum

Torque in N-m
Rated 400
S6-50% 480
Max. 600

S6-50%

Rated

Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.

0

20

40

60

80

100

120

0

1000

2000

3000

4000

5000

RPM

kW

Maximum kW

S6 (50%ED) kW

Continuous (S1) kW

Amps at Base Speed -
Cont Amps 137
S6 Amps 161
Max Amps 188

RPM

0

75

150

225

300

375

450

525

600

675

750

0

Torque in N-m

1000

2000

3000

4000

5000

Maximum

Torque in N-m
Rated 480
S6-50% 590
Max. 720

S6-50%

Rated

Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.

0

20

40

60

80

100

120

140

160

0

1000

2000

3000

4000

5000

RPM

kW

Maximum kW

S6 (50%ED) kW

Continuous (S1) kW

RPM

0

90

180

270

360

450

540

630

720

810

900

Torque in N-m

0

1000

2000

3000

4000

5000

Maximum

Torque in N-m
Rated 590
S6-50% 700
Max. 890

S6-50%

Rated

Amps at Base Speed -
Cont Amps 176
S6 Amps 200
Max Amps 242

Performance assumes regenerative
converter with 750V dc bus and
505V ac at motor.

Advertising