2-14

Commissioning Your 8720MC Analog Drive

Refer to the tables below for the linking relationship between the
8720MC I/O event variables and the digital output parameters.

Scaling of Auto Velocity
Analog Reference

This section provides the information you need to scale an auto
velocity analog reference. The default setting is 1000 rpm/10V.

To change the scale factor for the auto velocity analog reference,
perform the following procedure:

1. At the HIM, press the escape key get to the top level display then

depress ENTER. A message similar to the following appears:

2. Press either the up or down arrow key until the following appears:

3. Press ENTER. Press either the up or down arrow key until the

following appears:

Sinks

Typical Sources

Parameter
Number

Parameter

Parameter
Number

Parameter

663

Digital_Output_2

Link

330

At Programmed Speed

664

Digital_Output_3

331

Zero Speed

665

Digital_Output_4

332

Motor Speed Below Threshold

666

Digital_Output_5

334

Torque Above Limit

667

Digital_Output_6

335

Velocity Above Limit

668

Digital_Output_7

336

In Position

669

Digital_Output_8

339

Speed Below Minimum

670

Digital_Output_9

340

Speed Above Maximum

671

Digital_Output_10

526

High Winding Enable

527

Low Winding Enable

528

Enable Brake Solenoid

529

Auto Reference Enabled

530

Manual Mode Selected

583

Orient Complete

615

Shut Down Error

Choose Mode
Display

Choose Mode
Program

Choose File
I/O Interface

Advertising