Viewing the fault queue, Viewing the fault queue -3 – Rockwell Automation 8720MC Drives Integration Manual User Manual

Page 57

Advertising
background image

Publication 8720MC-IN002A-EN-P — December 2002

Troubleshooting Your 8720MC Servo Drive

3-3

Viewing the Fault Queue

Control Status mode on the HIM or Explore/Device Properties/Faults
tab in DriveExplorer let you view the fault queue.

To view the fault queue on the HIM:

1. Press any key from the status display. “Choose Mode” is shown.

2. Press the increment up key or the decrement down key to show

Control Status”.

3. Press enter to select Control Status

4. Press the increment up key or the decrement down key until

Fault Queue” is displayed.

5. Press enter to select “Fault Queue”

6. Press the increment up key or the decrement down key until

View Queue” is displayed.

7. Press enter to select “View Queue”

The fault queue can contain up to 8 faults. The 8720MC Drive reports
the faults using the following format.

Figure 3.1
Fault Queue Format

The number (1) on the display in the figure above indicates this faults
position within the fault queue.

The 8720MC fault queue can also be monitored with DriveExplorer.
The fault queue can be accessed through the Explore pull down
menu, the Device Properties command and the Faults tab.

B

u

s

R

e

g

u

l

a

t

o

r

F

1

4

0

4

1

Fault queue

indicator

Fault code

number

Fault Display

Position in

fault queue

30386-Bus

Advertising