Troubleshooting Your 8720MC Servo Drive

3-13

Display mode on the HIM or DriveExplorer allows the user to view
the command bits.

Parameter 718 - SCANport Logic Status

The 8720MC drive sends a status word to any SCANport connected
device via a SCANport communications adapter. This may used by an
A-B PLC to monitor the status of the drive. This may also be used for
diagnostic purposes. The structure of parameter 718 is as follows. The
12 character status messages are shown in italics.

If a bit is set true (1) the function is enabled.

Bit 0: Drive enabled - “Enabled

Bit 1: Drive auto enabled - “Auto Ref Ena

Bit 2: Rotation direction - “Rotate Dir

Bit 3: Drive O.k. - “Drive OK

Bit 4: Zero speed - “Zero Speed

Bit 5: At reference speed - “At Ref Speed

Bit 6: Orient complete - “Orient Done

Bit 7 Reserved

Bit 8 Brake solenoid enabled - “Brake Enable

Bit 9: Torque >/= Torque limit - “Torque Limit

Bit 10: High Winding Selected - “Hi Wind Sel

Bit 11: Low winding Selected - “Lo Wind Sel

Bit 12: Shut down fault - “Shutdn Fault”

Bit 13: Reserved

Bit 14: Reserved

Bit 15: Manual mode selected - “Manual Mode