SCANport Command Interface

4-7

Rotation Direction - The rotation direction bit is used to identify the
direction of motor rotation.

Manual Reference Selected - Whenever the digital or SCANport
interfaces select the manual reference the drive acknowledges this
state by setting the manual reference selected bit 15, SCANport Output
Status Word.

The table below describes the fixed assignments for the eight 16 bit
input data words and the eight 16 bit output data words.

SCANport Data Interface

In addition to the SCANport Logic Command word, the SCANport
Logic Status word, the SCANport Command Reference and the
SCANport Feedback Output there are 16 additional 16 bit words
which can be exchanged between an Allen-Bradley PLC and the drive.

Data Word

Data Link
Identifier

8720MC
Parameter
Assignment

Default Link

8720MC Data Description

Data Type
(16 bit word)

Input Word 0

Logic Command

717

717

SCANport Logic Command Word

Bit Pattern

Input Word 1

Command Reference 713

713

SCANport velocity/torque Input
Reference Value

Signed Integer

Input Word 2

Data In A1

725

36

SCANport Velocity Reference Value

Signed Integer

Input Word 3

Data In A2

726

258

Target Position
±32,768 resolution units

Signed Integer

Input Word 4

Data In B1

727

153

Orient Angle

Signed Integer

Input Word 5

Data In B2

728

259

Positioning Velocity

Signed Integer

Input Word 6

Data In C1

729

260

Positioning Acceleration

Signed Integer

Input Word 7

Data IN C2

730

222

Orient Speed

Signed Integer

Input Word 8

Data IN D1

731

154

Orient Options

Signed Integer

Input Word 9

Data In D2

732

Reserved

Signed Integer

Output Word 0

Logic Status

718

718

SCANport Logic Status Word

Bit Pattern

Output Word 1

Velocity Feedback

715

40

SCANport Velocity Feedback

Signed Integer

Output Word 2

Data Out A1

733

11

Shut Down Errors

Bit Pattern

Output Word 3

Data Out A2

734

129

8720MC Drive Errors

Bit Pattern

Output Word 4

Data Out B1

735

13

Drive Status

Bit Pattern

Output Word 5

Data Out B2

736

386

Motor Shaft power

Integer

Output Word 6

Data Out C1

737

254

Actual parameter set

Binary 0 -7

Output Word 7

Data Out C2

738

Reserved

Signed Integer

Output Word 8

Data Out D1

739

347

Velocity Error

Signed Integer

Output Word 9

Data Out D2

740

84

Torque Feedback

Signed Integer

Advertising