Publication 8720MC-IN002A-EN-P — December 2002

Troubleshooting Your 8720MC Servo Drive

3-7

Understanding the Fault
Parameters

Using the HIM module or DriveExplorer is an effective way of finding
the source of a drive fault. Several of the parameters are specifically
designed to annunciate drive status and faults. The following is a
description of the fault parameters. The 12 character fault messages
are shown in italics.

Parameter 11 - Shutdown Errors

This parameter is a bit pattern that identifies any active major fault
within the drive. IDN 00011, parameter 11 is a SERCOS standard
variable conforming to IEC Standard 61491. The structure of parameter
11 is:

If any bit is true (1) an error is indicated.

Bit 0 = Overload shut down - “Drive Ovrld”

Bit 1 = Amplifier over temperature shut-down - “Drive Ovrtmp

Bit 2 = Motor over temperature shut down - “Motor Ovrtmp

Bit 3 = Reserved

Bit 4 = Reserved

Bit 5 = Feedback error - “Feedback

Bit 6 = Commutation error - “Commutation”

Bit 7 = Overcurrent error - “Overcurrent

Bit 8 = Overvoltage error - “Bus Overvolt

Bit 9 = Undervoltage error - “Bus Undervlt”

Bit 10 = “Phase Loss

Bit 11 = Excess position error - “Follow Error

Bit 12 = “Communicate

Bit 13 = “Overtravel

Bit 14 = Reserved

Bit 15 = 8720MC Drive Specific error - “AB Specific