Regenerative power supply specifications – Rockwell Automation 8720MC Drives Integration Manual User Manual

Page 200

Advertising
background image

Publication 8720MC-IN001D-EN-P — December 2002

D-12

8720SM Motor Specifications and Performance Curves

Regenerative Power Supply Specifications

Because of the larger current requirements for motors from 45 to 75
kW a master 37 kW regenerative power supply (RPS) and a slave 37
kW RPS are required. Each master or slave RPS requires its own line
reactor, harmonic filter and varister. The master and slave RPS units
are designed to share the current loads equally so incoming AC fuses
and wiring should be sized accordingly.

Specifications for 8720MC-RPS Master and Slave(s) Regenerative Power Supplies with 750V dc Drives and 8720SM AC Motors

8720MC-RPS065 Regen. P.S.

Units

Power Supply Specifications

Motor catalog number

8720SM-

045S5NA

055S5PA

063S5QA

075S6SA

093S6TA

Drive amplifier catalog number

8720MC-

D097

D120

D120

D149

D180

Regenerative Power Supply catalog
number

8720MC-

RPS065
BM and BS

RPS065
BM and BS

RPS065
BM and BS

RPS065
BM and BS

RPS190
BM

AC input voltage AC+10/-15%

RMS Volts

380 to 460

380 to 460

380 to 460

380 to 460

380 to 460

Input frequency

Hz ±3%

50/60

50/60

50/60

50/60

50/60

Input power factor

0.98

0.98

0.98

0.98

0.98

Required input kVA

kVA

56.5

72.4

83.6

99.5

122.5

Required input current

Amps RMS

71

91

105

125

154

Required input 1 min current

Amps RMS

106.5

136.5

157.5

187.5

231

Required output kVA

kVA

49.3

60.6

69.4

83.2

101.9

Required output current

Amps DC

65.7

80.8

92.5

110.9

135.9

Required max current (1 min)

Amps DC

98

121

139

166

204

Design Bus voltage

Volts DC

750

750

750

750

750

Rated input kVA

kVA

100

100

100

100

150

Rated input current

Amps RMS

130

130

130

130

195

Rated input 1 min current

Amps RMS

196

196

196

196

292

Rated output kVA

kVA

90

90

90

90

135

Rated output current

Amps DC

128

128

128

128

192

Rated max output current (1 min)

Amps DC

192

192

192

192

288

Operating Temperature (open)

deg C

0 to 50

0 to 50

0 to 50

0 to 50

0 to 50

Operating Temperature (Nema1)

deg C

0 to 40

0 to 40

0 to 40

0 to 40

0 to 40

Storage temperature

deg C

-40 to 85

-40 to 85

-40 to 85

-40 to 85

-40 to 85

Ambient humidity

%

5 to 95%

5 to 95%

5 to 95%

5 to 95%

5 to 95%

Altitude

m (ft)

1000 (3300)

1000 (3300)

1000 (3300)

1000 (3300)

1000 (3300)

Shock

G peak for 11
ms

15

15

15

15

15

Vibration

mm (in)
Displacement
at 1g

0.152 (.0006)

0.152 (.0006)

0.152 (.0006)

0.152 (.0006)

0.152 (.0006)

Weight

kg (lbs)

38.6 (85)

108.9 (240)

108.9 (240)

108.9 (240)

108.9 (240)

Advertising