Application Note

SCC in Binary Synchronous Communications

10-13

9

SPECIAL CONDITION INTERRUPT SERVICE ROUTINE

o errors

Assembly complete

011E

GLOBAL
ENTRY

SPCOND

PROCEDURE

011E

93F0

PUSH

@Rl5, R0

0120

3A84

INB

RL0, RR0A+2

!READ ERRORS!

0122

FE23

!PROCESS ERRORS!

0124

C830

LDB

RL0, #%30

0126

3A8B6

OUTB

WR0A, RL0

!ERROR RESET!

0128

FE21

012A

C808

LDB

RL0, #%08

012C

3A86

OUTB

WR0A+2, RL0

!WAIT DISABLE, RxINT ON 1ST OR SP COND.!

012E

FE23

0130

C0D1

LDB

RL0, #%D1

0132

3A86

OUTB

WR0A+6, RL0

!HUNT MODE, REC. ENABLE!

0134

FE27

0136

C838

LDB

RL0, #%38

0138

3A86

OUTB

WR0A, RL0

!RESET HIGHEST IUS!

013A

FE21

013C

97F0

POP

R0, @Rl5

013E

7B00

IRET

0140

END SPCOND

END BISYNC