Comtech EF Data CDD-562L User Manual

Page 102

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

Quick Start Guide

MN/CDD564L.IOM

7–10

2

Enter ‘1’ to configure the first route.

3

Enter a suitable name (e.g., ‘test’)

4

Set IP Address to ‘172.16.10.0’

5

Set Number of Subnet Bits to ‘24.

6

For Interface to which route is destined to <E-Ethernet S-Satellite Enter : S>
select ‘S.

7

For HDLC address [SMALL NETWORK] in hex <0x1 - 0xFE, enter = 0000>:
select ‘1.

8

Per this example, the CDM-IP 2 Route Table should now display the following:

Route Name Dest IP/SNet Bits Next Hop MultiCast State

Route001...[test 172.16.10.0/24 0x1 N/A toSat]..1

9

Go to “Per Route” by pressing [E], then disable ‘HdrCompression’, ‘PayloadCompression’ and
‘3xDES’ by selecting ‘No’ (‘Clear’ for 3xDES) for each of these choices.


Finally,
perform the following steps on the Satellite IP Demodulator (CDD-56X) 3:

Step Task

1

From the CLI Main Menu, select the Route Table [R] submenu.

2

Enter ‘1’ to configure the first route.

3

Enter a suitable name (e.g., ‘ToCDMIP2’).

4

Set IP Address to ‘172.17.10.0’.

5

Set Number of Subnet Bits to ‘24’.

6

For Interface to which route is destined to <E-Ethernet S-Satellite Enter : S>
select ‘E’.

7

Set the Next-hop IP Address to ‘172.16.10.1’.

8

Per this example, the CDD-56X Demod 3 Route Table should now display the following:

Route Name Dest IP/SNet Bits Next Hop MultiCast State

Route001...[ToCDMIP2 172.17.10.0/24 172.16.10.1 N/A toEth]..1

9

If the Header Compression Feature is available on this demodulator, do the following:
From the CLI Main Menu, select Administration [A] Æ Features Configuration [F] Æ
RxHeaderCompression [H]
, then press ‘1’ to disable the Header Compression on ‘Demod 1’.


At this point the basic configuration is over and the user should be able to:

ƒ Ping PC 1 from PC 2 and vice versa;

Advertising
This manual is related to the following products: