Comtech EF Data CDD-562L User Manual

Page 240

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

Appendix D

MN/CDD564L.IOM

D–24

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Save System
Configuration
Parameters

SCS=

1 byte value
1 – Save config

Command only
Set to ‘1’ to save all the active system configuration on to the Flash.

SCS=
SCS!

N/A

SCS=x
(see Description of Arguments)

Software Revision N/A

34-37 bytes

Query only.
Returns the value of the internal software revision installed in the unit.
Example: >0001/SWR=Boot:1.1.1 Bulk1:1.5.1u Bulk2:1.5.1P

SWR!

SWR?

SWR=Boot:x.y.zz Bulk1:x.y.zz
Bulk2:x.y.zz
(see Description of Arguments)

Upgrade Slot

USI=

1 bytes, value of
0,1, or 2

Command or Query.
Slot to upgrade new IP firmware where:
0 = Oldest
1 = Image 1
2 = Image 2
Example: UPS=0

USI =
USI!

USI?

USI=x
(see Description of Arguments)

Unit Up Time

N/A

String value

Query only
Displays the unit up time in days, hours, minutes & seconds.
Example: >0001/UUT=0 days 0 hours 13 mins 15 secs

N/A

UUT?

UUT=sssssss
(see Description of Arguments)