3 lnb configuration (per lnb) page – Comtech EF Data CDD-562L User Manual

Page 136

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

CDD-56X CLI and Telnet Operation

MN/CDD564L.IOM

8–32

8.2.7.1.3

LNB Configuration (Per LNB) page

Access the LNB Configuration (Per Demod) page from the Configuration page. Note that all
parameters on this page are configurable on a per-LNB basis (as determined via Demod Select).

This page contains the following unique selections/fields:

Selection

Entry Description

LNB DC Supply Voltage

P

Select as [On] or [Off].

LNB 10MHz Reference Enable

R

Select as [On] or [Off].

LNB Current Alarm Lower Limit (mA)

C

Valid range is from 10 to 400 mA.

LNB Current Alarm Upper Limit (mA)

H

Valid range is from 50 to 600 mA.

LNB LO Frequency (MHz)

L

Valid range is from 3000 MHz to 65000 MHz.

LNB Current

[RO]

Displays active LNB current values on a per-LNB basis, when
the presence of an LNB is detected.

LNB Voltage

[RO]

Displays active LNB voltage values on a per-LNB basis, when

the presence of an LNB is detected.