4 mib-ii, 5 private mib, 1 administration group – Comtech EF Data CDD-562L User Manual

Page 84: 1 access lists subgroup, 2 features subgroup

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

Ethernet-based Remote Product Management

MN/CDD564L.IOM

6–4

6.3.4

MIB-II

The demodulator agent implements RFC 1213, Management Information Base for Network
Management of TCP/IP-based Internets. This is known as “MIB-II” or “Public MIB support.”
For detailed OID information please see the actual MIB file. The agent implements the
following Groups:

Table 6-1. MIB-II Support

Group

Comments

System Group

Mandatory for RFC1213

Interface

Mandatory for RFC1213

IP

Mandatory for RFC1213

ICMP

Mandatory for RFC1213

TCP

Mandatory for RFC1213

UDP

Mandatory for RFC1213

SNMP

Mandatory for RFC1213

Address Translation Group

Implemented but depreciated in MIB-II

EGP Not

applicable

6.3.5

Private MIB

The Private MIB holds all the security, feature selection, IP related parameters and all the
demodulator specific parameters. For detailed OID information please see the actual MIB file.

6.3.5.1 Administration Group

This group contains system security, administration, and feature configuration parameters.

6.3.5.1.1

Access Lists Subgroup

This subgroup allows the user to define which remote clients can connect to a demodulator when
the Access List Enforcement is enabled. Each entry allows the user to specify an IP address and a
subnet mask to define a unique class of clients that are allowed access to the unit.

6.3.5.1.2

Features Subgroup

This subgroup allows the user to enable/disable a Standard or FAST feature.

Standard features (ping reply, telnet, , IGMP, and multicast forwarding) can be enabled or disabled
by sending a 1 (enable) or 0 (disable).

Header decompression can be enabled or disabled on a per demodulator basis via the FeaturesTable.

Changing the Working mode between Point-to-Point Mode, Small Network Mode,
Large Network Mode, and Vipersat Mode forces the system to reboot. System
configuration will be saved before re-booting. Please make sure you are setting
the correct value.