1 igmp information page – Comtech EF Data CDD-562L User Manual

Page 127

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

CDD-56X CLI and Telnet Operation

MN/CDD564L.IOM

8–23

8.2.5.1 IGMP Information page

Access the IGMP information page from the Protocol Configuration page.














Use this page to view the IGMP clients that are actively listening to content being provided by the
demodulator. This page also helps to determine how the Ethernet Interface is configured, either to
receive requests to join IGMP groups or to announce groups for others to join. This page contains
the following unique selections/fields:

Selection

Entry Description

IGMP

[RO] Shows IGMP status as [Enabled] or [Disabled].

View IGMP Table

V

Reports the content that clients have subscribed to the demodulator

using the IGMP protocol. This Allows user to determine which

services are being used and the minimum time before a service will
be terminated.

CDM-IP as Server: IGMP query

period

Q

Requests that a server periodically publish to users on the LAN the

Multicast IP Addresses that it can service. The IGMP query period

defines the time interval (in seconds) between each of these

queries for membership.

CDM-IP as Server: IGMP max.
response time

R

Defines the time interval (in seconds) that the demodulator should
wait before it assumes that no parties are interested in the content

published via an IGMP query. This option is expressed in seconds,

and the max response time that is accepted by the demodulator is

25 seconds.

CDM-IP as Server: Number of

missed responses before leaving

IGMP group

M

Defines the number of membership queries that go unanswered

from LAN clients before the Ethernet Interface will no longer forward

data for that IGMP group.

For example, consider a demodulator that has the IGMP query
period set to 60 seconds, and the number of missed responses set

to 3. If a client joins an IGMP group, then the service to that group

will not be discontinued until no clients respond to a query from the

demodulator for a period of 60*3 = 180 seconds.

Advertising