1 rx configuration (per demod) page – Comtech EF Data CDD-562L User Manual

Page 134

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

CDD-56X CLI and Telnet Operation

MN/CDD564L.IOM

8–30

8.2.7.1.1

Rx Configuration (Per Demod) page

Access the Rx Configuration page from the Configuration page. Note that all parameters on this
page are configurable on a per-Demod basis (as determined via Demod Select).


















This page contains the following unique selections/fields:

Selection

Entry Description

Frequency

Q

CDD-562L/CDD-564L (L-Band): Valid ranges for Rx Frequency are

from 950 to 1950 MHz.

Data Rate

D

Valid range for Rx Data Rate is from 2.4 kbps to 9980 kbps.
Note: High data rate [>5000Kbps] is a FAST Feature to be purchased

from Comtech EF Data

FEC

T

Select one of the following for the Decoder Type:

1 – Uncoded
2 – TURBO

Note: Selection 2 (TURBO) available only with the CDD-564L.

Code Rate

R

Select one of the following for the Decoder Rate:

1 – 3/4

2 – 7/8
3 – 0.95

4 – 1/1

Demodulation

M

Select one of the following for the Rx Demodulation type:

1 – QPSK

2 – 8-PSK
3 – 16QAM

Note: Selections1, 2, 3 available only with the CDD-564L.

Spectrum Inversion

U

Select one of the following:

1 – NRM (Normal)

2 – INV (Inverted)

Data Inversion

I

Select one of the following:

1 – NRM (Normal)

2 – INV (Inverted)