2 l-band (cdd-562l, cdd-564l) – Comtech EF Data CDD-562L User Manual

Page 37

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

Introduction

MN/CDD564L.IOM

1–13

1.4.1.2 L-Band (CDD-562L, CDD-564L)

System Specification
Frequency Range

950 to 1950 MHz

Symbol Rate Range

16 ksps to 3.0 Msps

Data Rate Range Each demodulator independently in 1 bps increments

Rate 3/4 QPSK TPC 16 kbps to 4.5 Mbps

Rate 7/8 QPSK TPC 16 kbps to 5.25 Mbps

Rate 0.95 QPSK TPC 16 kbps to 5.666Mbps

Rate 3/4 8-PSK TPC 16 kbps to 6.75 Mbps
Rate 7/8 8-PSK TPC 16 kbps to 7.875 Mbps

Rate 0.95 8-PSK TPC 16 kbps to 8.5 Mbps

Rate 3/4 16-QAM TPC 16 kbps to 9.0 Mbps
Rate 7/8 16-QAM TPC 16 kbps to 9.98 Mbps

Descrambling

Comtech to IESS-315

FEC Turbo Product

Rate 3/4, 0.95 QPSK
Rate 3/4, 0.95 8-PSK
Rate 3/4, 16-QAM
Rate 7/8, QPSK, 8-PSK, 16-QAM

Inputs

CDD-562L: (2X) Type ‘N’ female
CDD-564L: (4X) Type ‘N’ female

Input Impedance

50

Ω, 17 dB minimum return loss

Traffic and Management Interface

10/100 BaseT Ethernet RJ-45

Command Line Interface (CLI)

EIA-232, RJ-11

Factory Test Connector

DB-9 male

Frequency Reference

Internal

± 0.06 ppm, 32 to 122°F (0 to 50°C)

External None

Demodulator
Input Power Range

-130 + 10 log (Symbol Rate) to –90 +10 Log (Symbol Rate)

Max Composite Level

+40 dBc, up to –5 dBm

Acquisition Range

± 1 to ± 32 kHz (1 kHz steps) < 625 ksps
± 1 to ± 200 kHz ≥ 625 ksps

Monitor Functions

Eb/No Frequency Offset, BER
LNB current and voltage
Rx signal level


Advertising