Comtech EF Data CDD-562L User Manual

Page 159

Advertising
background image

CDD-562L/564 Demodulator with IP Module

Revision 2

CDD-56X CLI and Telnet Operation

MN/CDD564L.IOM

8–55

Selection

Entry Description

Dump Packets sent to

EndStation

G

Select [Yes] or [No].

Selecting [Yes] forces the IP Module to dump a hexadecimal

representation of each packet that is received/destined for the

demodulator only.

Dump Packets received from

EndStation

H

Select [Yes] or [No].

Selecting [Yes] forces the IP Module to dump a hexadecimal

representation of each packet that is sourced from this unit and

destined for some other device. This Allows user to see what type of
packets this unit is generating internally.

Ping

P

Enter the IP address in aaa.bbb.ccc.ddd format to ping, on the same

subnet as CDD-56x unit.

Traceroute

A

Enter the IP address in aaa.bbb.ccc.ddd format

Command Line Debug Prompt

D

Enter the password to access the debug command line.
Note: This option is reserved for Customer Service and
engineering use only.